![cardio-Q-banner-background cardio-Q-banner-background](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q series](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q50 & Cardio Q70 product](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![cardio-Q-banner-background cardio-Q-banner-background](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q series](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q50 & Cardio Q70 product body](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 slide1](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 paper](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 product body](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 slide2](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 paper](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 product body](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 slide3](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 paper](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 product body](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 slide4](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 paper](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 product body](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 slide5](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 paper](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
![Cardio Q70 product body](http://www.ebionet.com/wp-content/plugins/revslider/public/assets/assets/dummy.png)
Why Cardio Q70?
Time Saving Intuitive Design
- AUTO Key: Supports simple 3-step workflow
- 10.1” wide color LCD touchscreen
- Onboard full alphanumeric keyboard
- Onboard Z-fold printer (Optional)
- Max. 10 hour high capacity battery
- Quick exam function without patient ID entry
- Barcode scanner via USB
- Device settings can be exported and imported by a USB drive
- Lead fault detection & notice
![Cardio Q70 product image](https://www.ebionet.com/wp-content/uploads/2022/01/Cardio-Q70-product-image04.jpg)
![Cardio Q70 product image](https://www.ebionet.com/wp-content/uploads/2022/01/Cardio-Q70-product-image03.jpg)
![CardioQ70 Full disclosure – Live mode](https://www.ebionet.com/wp-content/uploads/2022/01/Full-disclosure-–-Live-mode.jpg)
![CardioQ70 Real-time arrhythmia detection](https://www.ebionet.com/wp-content/uploads/2022/01/Real-time-arrhythmia-detection.jpg)
![CardioQ70 Long-term ECG recording](https://www.ebionet.com/wp-content/uploads/2022/01/Long-term-ECG-recording.jpg)
![special report text](https://www.ebionet.com/wp-content/uploads/2022/01/special-report-text.jpg)
![special report guide](https://www.ebionet.com/wp-content/uploads/2022/01/special-report-guide.jpg)
![special report st map](https://www.ebionet.com/wp-content/uploads/2022/01/special-report-st-map.jpg)
![special report vector](https://www.ebionet.com/wp-content/uploads/2022/01/special-report-vector.jpg)
Improved Clinical Decisions
- Preview screen before print-out
- Full disclosure for 30 minutes (Live mode available)
- Long-term ECG recording for 1, 3, 5,10, 20, 30 minute intervals
- Real-time arrhythmia detection (13 types)
- Heart Rate Variability(HRV) analysis
- Diagnostic interpretations (120 diagnoses)
- Custom reports for detailed interpretations and analysis (Text, ST segment and map, Guide, Vector)
- Spirometer (Optional): COPD, FVC, SVC, MVV
Comprehensive Documentation and Reports
- PACS, GDT, Web server, Direct EMR (Direct and bidirectional connectivity)
- Extended data storage (500 cases)
- Various standard file formats: PDF, XML, MFER, BMP, JPG
- USB connectivity for external memory, external keyboard or printer
- HDMI connectivity for external monitor
![CardioQ back image](https://www.ebionet.com/wp-content/uploads/2022/01/CardioQ-back-image.jpg)
![CardioQ data transfer process](https://www.ebionet.com/wp-content/uploads/2022/01/CardioQ-data-transfer-process.jpg)
![HIPAA-Compliant Security login](https://www.ebionet.com/wp-content/uploads/2022/01/HIPAA-Compliant-Security-login.jpg)
![HIPAA-Compliant Security setting](https://www.ebionet.com/wp-content/uploads/2022/01/HIPAA-Compliant-Security-setting.jpg)
HIPAA-Compliant Security
- Information is encrypted and protected
- Different ID, password, roles and authority by user
- Auto standby, shut down
- Hide patient name and hospital information
- Event log
Bionet Patented ST Map
- Visual information of ST segment deviation and spatial orientation
- Intuitive and easy understanding of each clinical location of subendocardial ischemia and transmural injury
- More frequent, quick, and accurate monitoring to enhance medical treatment for cases of myocardial ischemia
![stmap](https://www.ebionet.com/wp-content/uploads/2022/07/stmap.jpg)
![glasgovw algorithm](https://www.ebionet.com/wp-content/uploads/2022/07/glasgow-algorithm.jpg)
Glasgow Algorithm
- Use of age, sex, and race-based criteria in pediatric as well as adult ECG interpretation
- AHA / ACCF / HRS recommendations
- Highly effective STEMI (ST segment Elevation Myocardial Infarction) Interpretation
- Help ananlyze QTc measurements and assessment of cardiac risk
- Meets all IEC 60601-2-51 requirements and ISO 9001:2008 standards
* Glasgow algorithm will be marketed at Q70 in the second half of the year