October 27, 2026

How Does qCO Monitor Cardiac Output Noninvasively? Understanding ECG and Thoracic Impedance
Patient Monitor

How Does qCO Monitor Cardiac Output Noninvasively? Understanding ECG and Thoracic Impedance

Hello from Bionet! 😃

You’re probably familiar with heart rate, the number of times the heart beats in one minute.

But what do we call the amount of blood the heart pumps each minute?

That’s cardiac output (CO).

In this article, we’ll explain the basics of cardiac output and explore how qCO uses ECG and thoracic impedance signals for noninvasive monitoring.

How can we monitor cardiac output noninvasively? Cardiac Output Monitoring with qCO

Cardiac Output vs. Heart Rate: What’s the Difference?

Heart rate is the number of heartbeats per minute. Cardiac output is the volume of blood the heart pumps per minute.

Cardiac output is determined by heart rate and stroke volume:

Cardiac Output (CO) = Heart Rate (HR) × Stroke Volume (SV)

Stroke volume is the amount of blood the heart pumps with each beat.

This means that two people with the same heart rate can have different cardiac outputs if their stroke volumes differ. Heart rate and cardiac output are related, but they provide different information.

Different Approaches to Measuring Cardiac Output

One method of assessing cardiac output is thermodilution using a pulmonary artery catheter.

This method calculates cardiac output by measuring changes in blood temperature through a catheter inserted into the vascular system. The catheter can also provide additional hemodynamic information, including pressures within the heart and pulmonary artery.

Because this approach involves placing a device inside a blood vessel, catheter insertion and ongoing care require appropriate precautions.

qCO uses a noninvasive approach that collects signals through electrodes attached to the skin, without inserting an intravascular catheter.

The distinction lies in where the signals are collected and how they are analyzed.

Each method provides different information and has its own conditions for use. Clinicians select an appropriate method based on the patient’s condition and the information needed.

What Signals Does qCO Analyze?

qCO analyzes electrocardiographic (ECG) signals together with thoracic impedance signals.

An ECG records the heart’s electrical activity. Thoracic impedance describes the chest’s opposition to the flow of an electrical current and is influenced by factors including changes in blood flow during the cardiac cycle.

qCO analyzes the timing and waveform characteristics of these signals to derive information related to cardiac output.

The technique of analyzing changes in thoracic impedance to assess cardiac activity is called impedance cardiography (ICG).

1. Measurement Begins with Electrodes on the Skin

The qCO technical documentation describes a setup using four electrodes attached to the chest.

One pair applies an electrical current, while the other measures the resulting voltage changes. These measurements are used to record changes in thoracic impedance.

This process does not require a catheter to be inserted into a blood vessel or the heart to obtain cardiac output–related signals. Collecting signals through electrodes on the skin is a key feature of qCO’s noninvasive approach.

Even with a noninvasive method, the skin at the electrode sites and the conditions for use should be checked. The device should always be used in accordance with its instructions for use.

2. Why Analyze ECG and Impedance Waveforms Together?

ECG and impedance waveforms provide different types of information.

The ECG identifies the timing of electrical activity associated with each heartbeat. The impedance waveform reflects changes in thoracic impedance during the cardiac cycle.

qCO uses the R wave of the ECG as a timing reference and identifies characteristic points in the processed impedance waveform. It then uses this information to calculate cardiac output–related parameters.

The key to understanding qCO is that it analyzes the heart’s electrical activity alongside changes in thoracic impedance.

3. Signal Quality Matters Alongside the Readings

When analyzing physiological signals, it is important to consider signal quality as well as the displayed values.

Electrode contact, patient movement, and electrical interference can affect both ECG and impedance signals.

The qCO technical documentation also describes signal-processing methods designed to address these influences.

When reviewing measurements, electrode connections, signal quality, and measurement conditions should therefore be checked together.

These factors also matter when assessing changes over time. Available parameters and measurement ranges should be confirmed in the instructions for use for the specific device and software version.

Understanding Noninvasive Cardiac Output Monitoring with qCO

Heart rate tells us how often the heart beats. Cardiac output tells us how much blood it pumps each minute.

To obtain cardiac output–related information, qCO collects and analyzes ECG and thoracic impedance signals through electrodes attached to the skin.

Its noninvasive signal acquisition and combined analysis of these signals are central to understanding how the technology works.

We hope this article has helped clarify the principles behind qCO.

Bionet will continue to share accessible explanations of ECG technology, patient monitoring, and the physiological signals behind them. 💙


▶ Product and Technical Inquiries

✉️ marketing@ebionet.com

※ This article is based on qCO technical documentation and is intended to explain its measurement principles. For the intended use, available parameters, and precautions of a specific product, please refer to its locally approved labeling and instructions for use. Clinicians should select measurement methods and interpret results in the context of the patient’s condition, other physiological data, and clinical observations.